Solenoid-Saver® eliminates AC hum and reduces heat generation for many types of solenoids.
Controlled application of current prevents coil burnout if high pull-in/low holding current AC or DC solenoids fail to pull-in completely.
Can adapt high pull-in low holding current solenoids to special voltages & frequencies 12V to 250V DC or 12V to 240V AC wideband 25-800Hz.
Optional optical isolated control input 4 to 10V, 5MA, 20 usec or more (or other control voltages) to actuate any high current solenoid directly by computer or other low power signal source.
For coils of 1 ohm to 3,500 ohms DC resistance requiring up to 70 amps during pull-in up to 120 milliseconds. Basic solenoid coil voltage and resistance must be specified.