EXHIBIT WITH US Sign In

Safety relay UM-FA series

Safety relay UM-FA series

Safety relay UM-FA series

About


Monitors a wide variety of safety and non-safety input devices:Optical-based safeguarding devices, such as Safety Laser ScannersPositive-opening safety switches used for guard interlockingEmergency-stop devices, such as palm buttons and rope/cable pullsStandard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travelThe safety inputs can monitor:+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup+24V dc source that is switched by hard/relay contacts in single-channel or dual-channel hookupStandard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travelTb>UM-FA-9A: Three normally open (N.O.) output switching channels for connection to control-reliable power interrupt circuitsUM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching channels for connection to control-reliable power interrupt circuitsAutomatic reset or monitored manual reset, depending on hookupDesign complies with Category 4 PLe (ISO 13849-1), SIL 3 (IEC 61508/IEC 62061), and Control Reliable (ANSI B11.19)Safety Integrity Level (SIL) 3 (IEC 61508/62061)Performance level (PL) e (ISO 13849-1)For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN 60204-1



PARAMETERS

Parameter Name Parameter Value
Measured/monitored value
safety
Mounting
DIN rail
Trigger voltage
24 V