EXHIBIT WITH US Sign In

Safety relay INT-04 series

Safety relay INT-04 series

Safety relay INT-04 series

About


Monitors both contact on E-stop buttons
Incorporates loop break detection for floor mat sensing
Provides 2 safe outputs plus a form C output for signaling
Inhibits machine restart in case of component failure
DIN Rail or panel mount
LED power on indicator

The INT-04-024 or INT-04-120 Safety Relay is intended for use as a part of a safety circuit in emergency-stop of safety floor mat sensing applications. It is a safety relay which used positive-guided relays, configured for self-checking, to inhibit machine start-up in the event of an internal component failure.

The INT-04 Relay can also monitor contracts on external relays for controlling expansion block relays (INT-05 and INT-06).

As E-Stop Relay
Both contacts on E-stop buttons are monitored to ensure both have opened and closed to allow machine restart. Multiple contacts can be wired in series. Upon failure of either contact, the relay will prevent restart.

As Safety Floor Mat Relay
The INT-04 monitors both loops of a safety floor mat. The safety outputs of the INT-04 turn off when an operator steps on the mat. The relay incorporates loop break detection to turn off if one of the loops breaks or becomes disconnected.



PARAMETERS

Parameter Name Parameter Value
Measured/monitored value
safety
Contact configuration
2 NO
Applications
emergency stop
Mounting
  • DIN rail
  • panel-mount
Tripping current
1 A, 4 A, 24 A
Trigger voltage
24 V, 30 V, 120 V