- NO2 converter in a wall-mounting housing
- With heated gas inlet and outlet
- High-flow capacity
- Long service life
- Catalyst cartridge easy to change without any tools
- Operating temperature adjustable up to +680 °C [+ 1256 °F]
- Power: 115 V
- Material of sample-contacting parts: stainless steel, Viton®, PVDF, PTFE
In many countries, clean-air regulations require a continuous measurement of nitrogen oxides NOx, as the sum of nitrogen dioxide NO2 and nitrogen monoxide NO, for combustion processes as soon as the share of NO2 exceeds 5 % of the total NOx emission. Due to the conversion to NO, the use of a standard NO analyzer is possible.
Gas converter type CG‑2H‑W for wall‑mounting, heated sample gas inlet, without bypass valve, thermally insulated compact tube furnace, electrically heated with thermocouple Ni‑CrNi and electronic temperature controller, adjustable from 50 to 680 °C, high and low‑temperature alarm, gas inlet: 6 mm SS or on request 8 mm SS, gas outlet: 6 mm SS, material: SS 316Ti, Viton®, PVDF, PTFE, power: 115 V/60 Hz, 610 VA, without catalyst cartridge