EXHIBIT WITH US Sign In

Data-logger with external sensor DL.WMS series

Data-logger with external sensor DL.WMS series

Data-logger with external sensor DL.WMS series

About


Pressure measuring range: 5 mH2O … 250 mH2O
Accuracy: ≤ ± 0.10 % FS
Temperature measuring range: -5 … 80°C
Operating temperature: -5 … 80 / -5 … 50°C (Datalogger)
Process temperature: -5 … 80°C
Radio interface: 433 MHz
Frequency band: 900/2100 MHz
Materials level transmitter: Stainless steel, titanium
Materials Datalogger: Plastic, stainless steel
Features: 250’000 measurement values, measurement interval 2s…12h, battery operation, online programmable, housekeeping data (temperature, humidity, battery voltage)

Customer Benefits
Precise piezoresistive multi-parameter probe for pressure and temperature
USB radio interface for data download or configuration
Flood proof communication unit (IP68)
Humidity, temperature and battery voltage of the device are constantly monitored
Can be installed into 2” tubes
User-friendly web-based software solution



PARAMETERS

Parameter Name Parameter Value
Measured quantity
conductivity, pH, depth
Connector type
USB, radio frequency, GSM / GPRS, online
Display
without display
Applications
  • for monitoring
  • for harsh environments
  • for battery
Other characteristics
  • programmable
  • battery-powered
  • multi-channel
  • stand-alone
  • rugged
  • with external sensor
  • IP67
  • IP68
  • submersible
  • with web interface
  • with automatic report generation
  • with replaceable sensor
  • modular

Offer by